Throughput per hour, native (uncompressed): | T9840B (64 drives, 19 MB/sec) 4.4 TB/hr T9840C (64 drives, 30 MB/sec) 6.9 TB/hr T9940B (64 drives, 30 MB/sec) 6.9 TB/hr LTO Gen 2 (64 drives, 3035 MB/sec) up to 8.1 TB/hr LTO Gen 3 (64 drives, 80 MB/sec) up to 18.4 TB/hr SDLT 600 (64 drives, 36 MB/sec) 8.3 TB/hr
| T9840B (2,048 drives, 19 MB/sec) 140 TB/hr T9840C (2,048 drives, 30 MB/sec) 221 TB/hr T9940B (2,048 drives, 30 MB/sec) 221 TB/hr LTO Gen 2 (2,048 drives, 3035 MB/sec) up to 258 TB/hr LTO Gen 3 (2,048 drives, 80 MB/sec) up to 590 TB/hr SDLT 600 (2,048 drives, 36 MB/sec) 265 TB/hr
|
Audit time: | <60 min
| <60 min
|
Average cell to drive time: | 5 sec
| 5 sec
|
Capacity, native (uncompressed): | T9840B (1,448 carts, 20 GB/cart) 29 TB T9840C (1,448 carts, 40 GB/cart) 58 TB T9940B (1,448 carts, 200 GB/cart) 290 TB LTO Gen 2 (1,448 carts, 200 GB/cart) 290 TB LTO Gen 3 (1,448 carts, 400 GB/cart) 579 TB SDLT 600 (1,448 carts, 300 GB/cart) 434 TB
| T9840B (300,000 carts, 20 GB/cart) 6 PB T9840C (300,000 carts, 40 GB/cart) 12 PB T9940B (300,000 carts, 200 GB/cart) 60 PB LTO Gen 2 (300,000 carts, 200 GB/cart) 60 PB LTO Gen 3 (300,000 carts, 400 GB/cart) 120 PB SDLT 600 (300,000 carts, 300 GB/cart) 90 PB
|
Number of cartridge slots: | Starts at 1,448 carts customer-usable slots
| 300,000 customer-usable slots
|
Number of tape drives / types: | Up to 64 drives of any combination of supported drives, including: T9840 ESCON, Fibre Channel and FICON, T9940 ESCON, Fibre Channel and FICON, LTO Ultrium Generation Fibre Channel, SDLT Fibre Channel
| Up to 2,048 drives of any combination of supported drives, including: T9840 ESCON, Fibre Channel and FICON, T9940 ESCON, Fibre Channel and FICON, LTO Ultrium Generation Fibre Channel, SDLT Fibre Channel
|
Cartridge access port (CAP): | Standard 39 cartridge slot CAP, optional 39 additional slots (78 total)
| Up to 2,496 cartridge slots
|
Mean exchanges / swaps between failure (MEBF/MSBF): | 2,000,000
| 2,000,000
|
Non-disruptive serviceability: | Standard N+1 power for drives, robotics and library electronics that can be replaced while the library is operating.
| Standard N+1 power for drives, robotics and library electronics that can be replaced while the library is operating.
|
Supported host platforms: | All major operating systems
| All major operating systems
|
Robotics control interfaces: | TCP/IP (IEEE 802.3, 100 baseT, half-duplex)
| TCP/IP (IEEE 802.3, 100 baseT, half-duplex)
|
Any Cartridge Any Slot technology: | Both minimum and maximum configurations support full mixed media, any cartridge can be placed in any cell, no required partitions
| Both minimum and maximum configurations support full mixed media, any cartridge can be placed in any cell, no required partitions
|
Digital vision system: | Unique digital vision camera system performs continuous calibration and reads bar codes
| Unique digital vision camera system performs continuous calibration and reads bar codes
|
Operator panel: | Standard web-accessible monitoring and control
| Standard web-accessible monitoring and control
|
Automatic clean: | Additional dedicated cleaning cartridge slots are included for tape drive cleaning for multiple drive types by library or software command
| Additional dedicated cleaning cartridge slots are included for tape drive cleaning for multiple drive types by library or software command
|
Automatic self discovery: | Auto-discovery and auto-configuration for all drive, media types, slots and CAP
| Auto-discovery and auto-configuration for all drive, media types, slots and CAP
|
Continuous automation calibration: | No periodic maintenance or alignment required
| No periodic maintenance or alignment required
|
Height: | 93.15 in (236.6 cm)
| 93.15 in (236.6 cm)
|
Depth: | 109 in (276.9 cm)
| 296.5 in (753 cm)
|
Width: | 67.25 in (170.8 cm)
| 2,338 in (5,938 cm)
|
Weight: | 6,250 lb (2,835 kg)
| 492K lb (223mg)
|
Temperature (operating): | +60° to +90° F (+16° to +32° C)
| +60° to +90° F (+16° to +32° C)
|
Temperature (non-operating): | +40° to +90° F (+4° to +32° C)
| +40° to +90° F (+4° to +32° C)
|
Relative humidity (operating): | 20%-80%
| 20%-80%
|
Relative humidity (non-operating): | 20%-80%
| 20%-80%
|
Voltage: | Choice of 220240 VAC @ 5060 Hz single phase or three phase (Delta, Wye or SUVA). Optional redundant inputs of any of the above.
| Choice of 220240 VAC @ 5060 Hz single phase or three phase (Delta, Wye or SUVA). Optional redundant inputs of any of the above.
|
Power consumption/dissipation: | varies by configuration
| varies by configuration
|
Drives: | Drive power consumption varies. Refer to individual drive specifications
| Drive power consumption varies. Refer to individual drive specifications
|
Safety: | UL listed to UL 60950 (latest edition); CSA standard CAN/CSA-C22.2, no. 60950 (latest edition); IEC Compliance EN60950, TUV compliance EN60950 (latest edition)
| UL listed to UL 60950 (latest edition); CSA standard CAN/CSA-C22.2, no. 60950 (latest edition); IEC Compliance EN60950, TUV compliance EN60950 (latest edition)
|
Emissions: | FCC Title 47, Part 15, Subpart B, Class A; VCCI Class A (C1SPR22); European Union CE emissions standards 89/336; AS/NZS 3548; Canada ICES-003, Taiwan (CNS13438)
| FCC Title 47, Part 15, Subpart B, Class A; VCCI Class A (C1SPR22); European Union CE emissions standards 89/336; AS/NZS 3548; Canada ICES-003, Taiwan (CNS13438)
|
Immunity: | European Union CE immunity standards (CISPR24/EN55024)
| European Union CE immunity standards (CISPR24/EN55024)
|